Content | Total (n=290) | Tertiary hospital (n=129) | Secondary Hospital (n=161) | |||
---|---|---|---|---|---|---|
Quantity | Percentage (%) | Quantity | Percentage (%) | Quantity | Percentage (%) | |
Filter membrane device installed at the terminal of final rinse water (before water discharge) | ||||||
 Yes | 238 | 82.07 | 109 | 84.5 | 129 | 80.12 |
 No | 52 | 17.93 | 20 | 15.5 | 32 | 19.88 |
Pore size of terminal filter membrane for final rinse water (n=238) | ||||||
 0.1μm | 40 | 16.81 | 19 | 17.43 | 21 | 16.28 |
 0.2μm | 182 | 76.47 | 86 | 78.9 | 96 | 74.42 |
 0.4μm | 10 | 4.20 | 0 | 0 | 10 | 7.75 |
 Other pore size | 6 | 2.52 | 4 | 3.67 | 2 | 1.55 |
Replacement cycle of terminal filter membrane for final rinse water (n=238) | ||||||
 Weekly | 1 | 0.42 | 0 | 0 | 1 | 0.78 |
 Monthly | 9 | 3.78 | 4 | 3.67 | 5 | 3.88 |
 Quarterly | 78 | 32.77 | 40 | 36.7 | 38 | 29.46 |
 Half-yearly | 34 | 14.29 | 21 | 19.27 | 13 | 10.08 |
 Yearly | 51 | 21.43 | 22 | 20.18 | 29 | 22.48 |
 Replaced but not in a fixed cycle | 62 | 26.05 | 21 | 19.27 | 41 | 31.78 |
 No replacement | 3 | 1.26 | 1 | 0.92 | 2 | 1.55 |
Filter membrane replacement department (n=235) | ||||||
 Third-party company | 120 | 51.06 | 57 | 52.78 | 63 | 49.61 |
 Hospital equipment/general affairs/logistics department | 100 | 42.55 | 46 | 42.59 | 54 | 42.52 |
 Replaced by the department | 15 | 6.38 | 5 | 4.63 | 10 | 7.87 |
Is there a disinfection device at the terminal of the final rinse water | ||||||
 Yes | 153 | 52.76 | 73 | 56.59 | 80 | 49.69 |
 No | 137 | 47.24 | 56 | 43.41 | 81 | 50.31 |
Number of terminal disinfection method types used for final rinse water (n=153) | ||||||
 1 | 107 | 69.93 | 52 | 71.23 | 55 | 68.75 |
 2 | 34 | 22.22 | 15 | 20.55 | 19 | 23.75 |
 3 | 12 | 7.84 | 6 | 8.22 | 6 | 7.50 |
Type of terminal disinfection device for final rinse water (n =153) | Â | Â | Â | Â | Â | Â |
 UV | 65 | 42.48 | 27 | 36.99 | 38 | 47.5 |
 Ozone | 55 | 35.95 | 23 | 31.51 | 32 | 40.00 |
 Chemical disinfection | 89 | 58.17 | 50 | 68.49 | 39 | 48.75 |
 Other disinfection methods | 2 | 1.31 | 0 | 0 | 2 | 2.50 |
Disinfection frequency of water supply pipeline | ||||||
 Daily | 5 | 1.72 | 3 | 2.33 | 2 | 1.24 |
 Monthly | 25 | 8.62 | 12 | 9.30 | 13 | 8.07 |
 Weekly | 27 | 9.31 | 16 | 12.40 | 11 | 6.83 |
 Quarterly | 54 | 18.62 | 28 | 21.71 | 26 | 16.15 |
 Half-yearly | 10 | 3.45 | 7 | 5.43 | 3 | 1.86 |
 Yearly | 17 | 5.86 | 10 | 7.75 | 7 | 4.35 |
 Disinfect but not at a fixed frequency | 51 | 17.59 | 23 | 17.83 | 28 | 17.39 |
 Not disinfected | 101 | 34.83 | 30 | 23.26 | 71 | 44.10 |
Type of chemical disinfectant used for disinfection of water supply pipeline (n=189) | ||||||
 Chlorine-containing disinfectant | 91 | 48.15 | 37 | 37.37 | 54 | 60.00 |
 Peracetic acid | 66 | 34.92 | 42 | 42.42 | 24 | 26.67 |
 Hydrogen peroxide | 13 | 6.88 | 7 | 7.07 | 6 | 6.67 |
 Other chemical disinfectants (ozone, chlorine dioxide, acidified water, etc.) | 19 | 10.05 | 13 | 13.13 | 6 | 6.67 |
Department for water supply pipeline disinfection (n=189) | ||||||
 Third-party company | 63 | 33.33 | 35 | 35.35 | 28 | 31.11 |
 Hospital equipment/general affairs/logistics department | 79 | 41.80 | 46 | 46.46 | 33 | 36.67 |
 Replaced by the department | 44 | 23.28 | 17 | 17.17 | 27 | 30.00 |
 Infection control department | 3 | 1.59 | 1 | 1.01 | 2 | 2.22 |