Skip to main content

Table 3 Comparative analysis of the rates of MDRO detection in sputum samples with and without duplication

From: Implications of deduplication on the detection rates of multidrug-resistant organism (MDRO) in various specimens: insights from the hospital infection surveillance program

MDRO

Without deduplication

With deduplication

X2

P

CRKP

CRKP

592

283

31.797

 < 0.001

KP

2085

1416

Detection rate

28.39%

19.99%

CRECO

CRECO

14

9

0.001

0.977

ECO

381

242

Detection rate

3.67%

3.72%

CRAB

CRAB

2048

858

77.652

 < 0.001

AB

2688

1362

Detection rate

76.19%

63.00%

CRPA

CRPA

1133

508

27.669

 < 0.001

PA

2413

1335

Detection rate

46.95%

38.05%

MRSA

MRSA

562

367

5.359

0.021

SA

798

569

Detection rate

70.43%

64.50%

  1. CRKP Carbapenem-resistant Klebsiella pneumoniae, KP Klebsiella pneumoniae, CRECO Carbapenem-resistant Escherichia coli, ECO Escherichia coli, CRAB Carbapenem-resistant Acinetobacter baumannii, AB Acinetobacter baumannii, CRPA Carbapenem-resistant Pseudomonas aeruginosa, PA Pseudomonas aeruginosa, MRSA methicillin-resistant Staphylococcus aureus, SA Staphylococcus aureus